Czech stove manufacturer
+420 491 422 647
Home/Accessories/Warm-air distribution/Fittings, reducers, connectors/Distribution Box 160/4x125 mm (Rocket), Galvanised

Description

The distribution box is used to distribute warm air from a single heat source (e.g. a fireplace insert) to several rooms. Heating several rooms from a single heat source is cost-effective and lets you control where the heat goes and how much of it.

Remember that:

  • The heat output of the fireplace insert must always be sufficient, depending on whether you will use the fireplace as your main heating or only as supplementary heating (background heat).
  • An adequate air supply must be provided to the room from which the ducts run and where the fire burns in the fireplace insert.
  • Except in the simplest warm-air distribution set-ups (e.g. an outlet to the upper floor only), a fan of suitable capacity needs to be fitted in the system.
  • All warm-air outlets must be closable and, where possible, continuously adjustable, so that you only ever heat the spaces you want to heat.
  • If you blow air into a room, you need to make sure the cooled air has a way to flow back out. The room must not be completely sealed (typically with uPVC windows and doors) — otherwise the necessary amount of warm air cannot be delivered to it.

Distribution Box 160/4x125 mm (Rocket), Galvanised

Code: HSF18-070

The distribution box distributes warm air from a single stove outlet into several branches of the distribution system at once. Rocket design, 160/4x125mm, galvanised.

€33
incl. VAT
Delivery within 7 days
✓ Dispatched once restocked✓ 2 years warranty✓ Free advice
  • The heat output of the fireplace insert must always be sufficient, depending on whether you will use the fireplace as your main heating or only as supplementary heating (background heat).
  • An adequate air supply must be provided to the room from which the ducts run and where the fire burns in the fireplace insert.
  • Except in the simplest warm-air distribution set-ups (e.g. an outlet to the upper floor only), a fan of suitable capacity needs to be fitted in the system.
  • All warm-air outlets must be closable and, where possible, continuously adjustable, so that you only ever heat the spaces you want to heat.
  • If you blow air into a room, you need to make sure the cooled air has a way to flow back out. The room must not be completely sealed (typically with uPVC windows and doors) — otherwise the necessary amount of warm air cannot be delivered to it.

Downloads

Manufacturer

Parkanex

Frequently bought together

Similar products