Czech stove manufacturer
+420 491 422 647
Home/Accessories/Warm-air distribution/Fittings, reducers, connectors/Distribution box 160/4x125 mm (cube), galvanised

Description

The distribution box is used to distribute warm air from a single heat source (e.g. a fireplace insert) to several rooms. Cube-shaped, measuring 160/4×125 mm, made of galvanised steel.

When installing a warm-air distribution system, remember:

  • The heat output of the fireplace or fireplace insert must always be sufficient for your needs, depending on whether you will use the fireplace as your main heating or only as supplementary heating (background heat).
  • An adequate air supply must be provided to the room from which the ducts run and where the fire burns in the fireplace insert.
  • Except in the very simplest warm-air distribution set-ups (e.g. an outlet to the upper floor only), a fan of suitable capacity needs to be fitted in the system.
  • All warm-air outlets must be closable and, where possible, continuously adjustable, so that you only ever heat the spaces you actually want to heat.
  • If you blow air into a room, you must also make sure the cooled air has a way to return. Slight overpressure does no harm, but if the room were completely sealed (typically with uPVC windows and doors), the necessary amount of warm air would not get into it.

Distribution box 160/4x125 mm (cube), galvanised

Code: HSF18-007

The distribution box distributes warm air from a single stove outlet into several branches of the ducting at once. Cube design, 160/4x125mm, galvanised.

€25
incl. VAT
Delivery within 6 days
✓ Dispatched once restocked✓ 2 years warranty✓ Free advice
  • The heat output of the fireplace or fireplace insert must always be sufficient for your needs, depending on whether you will use the fireplace as your main heating or only as supplementary heating (background heat).
  • An adequate air supply must be provided to the room from which the ducts run and where the fire burns in the fireplace insert.
  • Except in the very simplest warm-air distribution set-ups (e.g. an outlet to the upper floor only), a fan of suitable capacity needs to be fitted in the system.
  • All warm-air outlets must be closable and, where possible, continuously adjustable, so that you only ever heat the spaces you actually want to heat.
  • If you blow air into a room, you must also make sure the cooled air has a way to return. Slight overpressure does no harm, but if the room were completely sealed (typically with uPVC windows and doors), the necessary amount of warm air would not get into it.

Drawings and dimensions

Downloads

Manufacturer

Parkanex

Frequently bought together

Similar products