Czech stove manufacturer
+420 491 422 647

Description

Heating several rooms from a single heat source using warm-air distribution was already known to the ancient Greeks, Romans and Koreans. The economic advantages of this way of heating are obvious. It is always better to use one heat source for several places, especially if you can control where the heat goes, how much of it goes there and at what temperature.

Remember that:

  • The heat output of the fireplace (fireplace insert) must always be sufficient for whether we will use it as the main heating or only as supplementary heating (background heat).
  • There must be an adequate air supply to the room from which the ducting runs and where the fire burns in the fireplace insert.
  • Except in the very simplest warm-air distribution systems, such as ducting air only to the upper floor, a fan of the required capacity must be fitted in the system.
  • All warm-air outlets must be closable and, where possible, continuously adjustable, so that we always heat only the spaces we really want to heat.
  • If we blow air into a room, we must also make sure that the cooled air has a way to flow back out. Slight overpressure does no harm, but if the room were completely sealed – which is common with uPVC windows and doors – we would not get the required amount of warm air into it.

YR Splitter 150/2x100mm, Galvanised

Code: HSF18-093

The YR splitter divides warm air from one outlet into two branches of the ducting. Size 150/2x100mm, galvanised.

€13
incl. VAT
In stock
✓ Dispatched within 24 hours✓ 2 years warranty✓ Free advice
  • The heat output of the fireplace (fireplace insert) must always be sufficient for whether we will use it as the main heating or only as supplementary heating (background heat).
  • There must be an adequate air supply to the room from which the ducting runs and where the fire burns in the fireplace insert.
  • Except in the very simplest warm-air distribution systems, such as ducting air only to the upper floor, a fan of the required capacity must be fitted in the system.
  • All warm-air outlets must be closable and, where possible, continuously adjustable, so that we always heat only the spaces we really want to heat.
  • If we blow air into a room, we must also make sure that the cooled air has a way to flow back out. Slight overpressure does no harm, but if the room were completely sealed – which is common with uPVC windows and doors – we would not get the required amount of warm air into it.

Drawings and dimensions

Downloads

Manufacturer

Parkanex

Frequently bought together

Similar products