Czech stove manufacturer
+420 491 422 647

Description

The rosette provides a decorative finish for 100 mm diameter aluminium ducting where it passes through a wall or ceiling. The chrome-plated surface gives it an attractive look suited to interiors.

Use in a warm-air distribution system

Heating several rooms from a single heat source by means of warm-air distribution is a cost-effective solution. One heat source supplies several rooms, and you can control where the heat goes, how much of it and at what temperature.

Remember these rules when installing the system

  • The heat output of the fireplace or fireplace insert must be sufficient, depending on whether the fireplace will be your main heating or only supplementary heating.
  • A sufficient air supply must be ensured to the room from which the ducts run and where the fire burns in the fireplace insert.
  • Except for the simplest cases (e.g. an air outlet to the upper floor only), a fan of adequate capacity must be fitted into the system.
  • All warm-air outlets must be closable and, if possible, continuously adjustable, so that only the required rooms are heated.
  • If air is blown into a room, there must be a way for the cooled air to get back. Slight overpressure is not a problem, but with uPVC windows and doors a room can be so airtight that it will not be possible to get enough warm air into it.

Rosette for 100mm Aluminium Pipe, chrome

Code: HSF18-098

The chimney rosette covers the point where the flue pipe passes through a wall or ceiling and gives the installation a neat finish. Diameter 100 mm, chrome.

Colour options
WhiteChrome
€10
incl. VAT
In stock
✓ Dispatched within 24 hours✓ 2 years warranty✓ Free advice
  • The heat output of the fireplace or fireplace insert must be sufficient, depending on whether the fireplace will be your main heating or only supplementary heating.
  • A sufficient air supply must be ensured to the room from which the ducts run and where the fire burns in the fireplace insert.
  • Except for the simplest cases (e.g. an air outlet to the upper floor only), a fan of adequate capacity must be fitted into the system.
  • All warm-air outlets must be closable and, if possible, continuously adjustable, so that only the required rooms are heated.
  • If air is blown into a room, there must be a way for the cooled air to get back. Slight overpressure is not a problem, but with uPVC windows and doors a room can be so airtight that it will not be possible to get enough warm air into it.

Downloads

Manufacturer

Parkanex